What [fire safety](https://www.hawkswift.co.uk/blog/competent-person-duties-under-article-18-of-the-rro-2005) Signs Are Required by Law in the Workplace?
Understanding what fire safety signs are required by law in the workplace is a fundamental part of managing a commercial premises. Under the Regulatory Reform (Fire Safety) Order 2005 (RRO), the responsible person must ensure that clear and appropriate fire safety signage is provided and maintained.
Fire safety signs are not just a bureaucratic box-ticking exercise; they provide critical, life-saving information to employees, contractors, and visitors, particularly during an emergency when stress levels are high and visibility may be reduced. This guide outlines the core signage requirements for UK workplaces.
The Legal Framework for Fire Signage
The primary legislation governing fire safety in England and Wales is the Regulatory Reform (Fire Safety) Order 2005. In Scotland, similar duties are outlined in the Fire (Scotland) Act 2005 and the associated Fire Safety (Scotland) Regulations. Under the RRO, the responsible person—usually the employer, owner, or occupier of the premises—has a legal duty to provide general fire precautions.
This duty explicitly includes the requirement to provide and maintain suitable fire safety signs. Furthermore, the Health and Safety (Safety Signs and Signals) Regulations 1996 require employers to use specific safety signage where risks cannot be adequately controlled by other means.
To determine exactly which signs your premises need, a documented fire risk assessment is required. Guidance such as PAS 79 provides a recognised framework for conducting these assessments, ensuring all signage recommendations are proportionate to the risks present.
Mandatory Fire Action Notices
One of the most critical pieces of signage in any workplace is the fire action notice. These notices consolidate essential emergency instructions into a single, highly visible sign. While there is no single statutory format mandated by the government, best practice and British Standards (such as BS 5499) dictate that they must clearly display specific information.
A compliant fire action notice should typically include:
- Instructions on what to do upon discovering a fire (e.g., operate the nearest alarm).
- Instructions on what to do upon hearing the fire alarm (e.g., leave the building immediately).
- The location of assembly points.
- Contact details for the emergency services (999).
- Any specific instructions, such as "do not return to the building until told it is safe."
These notices should be placed in prominent, highly trafficked locations, particularly next to manual call points and at main building exits.
Fire Exit and Escape Route Signs
Under the RRO, escape routes must be clearly indicated so that occupants can safely leave the premises without assistance. Fire exit signs are mandatory in any building where the exit route is not immediately obvious to someone unfamiliar with the layout.
Signage must use standardised pictograms to ensure universal understanding. In the UK, you will typically encounter two main design conventions:
- BS 5499 signs: These feature a running man and a directional arrow, often accompanied by text such as "FIRE EXIT".
- Eurosigns (ISO 7010): These are similar in design but feature a slightly different pictogram and are increasingly common in modern buildings.
It is important not to mix different sign types within the same escape route, as this can cause confusion during an evacuation. Signs must be illuminated and clearly visible at all times, which may require the use of photoluminescent (glow-in-the-dark) signs or dedicated emergency lighting.
Fire Equipment Identification Signs
The law requires that fire fighting equipment is easily accessible and identifiable. If a fire extinguisher, fire alarm call point, or hose reel is not in plain view or is located in a recess, it must be indicated by a fire equipment sign.
These signs are categorised by colour:
- Red signs with white text are used for fire fighting equipment, such as fire extinguishers, hose reels, and fire blankets.
- Red and white signs indicate fire alarm call points.
Signs should be mounted at a sufficient height to be seen from a distance, and they must accurately describe the type of equipment present. For example, an extinguisher sign should indicate whether it contains water, CO2, or foam, helping users select the correct equipment for the specific fire hazard.
Supplementary and Prohibition Signs
Depending on the layout and risks within your premises, additional signage may be required to maintain compliance.
Prohibition signs are round, red signs with a diagonal line through a black pictogram. The most common example in a workplace is the "No Smoking" sign, which is legally required in many commercial premises. Other examples include "Do Not Use Lifts" during a fire emergency, which should be prominently displayed in lift lobbies.
Safe condition signs are square or rectangular, green signs with white text or pictograms. These indicate safe routes, such as the location of first-aid rooms or emergency escape routes. While green fire exit signs are standard, additional safe condition signs may be needed if your premises has specific safety features, such as a refuge area for disabled occupants.
Maintenance and Review of Fire Signs
Fire safety signs are only effective if they are accurate, legible, and well-maintained. As part of your ongoing fire safety management duties, signage should be included in your regular fire safety inspections.
Signs can become obscured by stored goods, damaged by daily operations, or faded by sunlight. If the layout of your premises changes—such as a new partition wall blocking an escape route—your signage must be updated immediately to reflect the new reality. Any changes to your fire strategy should be recorded in your fire risk assessment.
How HawkSwift Can Help
Determining the exact signage requirements for a complex commercial building can be challenging. If you are unsure whether your current fire safety signs meet the requirements of the Regulatory Reform (Fire Safety) Order 2005, HawkSwift Ltd can help. Our NEBOSH-qualified assessors provide comprehensive fire risk assessments starting from £199 + VAT, with detailed reports delivered within 48 hours. To ensure your premises is fully compliant and your occupants are protected, book a fire risk assessment with our team today.